Features
- TEMPERATURE RANGE: OPERATING 0℃ -- 40℃; STORAGE TEMPERATURE: -20℃ – 80℃
- HOLD UP TIME: 16mS MINIMUM AT NOMINAL INPUT VOLTAGE
- EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD
- LEAKAGE CURRENT: 3.5 mA. MAX. AT NOMINAL VOLTAGE 250VAC
- POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
- OVER POWER PROTECTION: 110%~160%
- OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.5~6.5V, +12V→13.2~15.6V
- OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→ 27.5~37.5A, +12V→45.1~65.6A
- SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB
- SAFETY: TO MEET UL, TUV, CB, CCC, RFI/EMI STANDARDS
- EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
- REMOTE ON/OFF CONTROL
- I2C FEATURES (OPTIONAL)
| Output Wattage: |
500W |
| Best Solution For: |
Server, Workstation, Storage System |
| Dimension: |
185.00x150.00x86.00 (mm)
7.28x5.91x3.39 (inch) |
| AC Input Spec: |
VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 8/4A AT ANY LOW/HIGH
RANGE INPUT VOLTAGE
INRUSH CURRENT: 25A MAX. FOR 110 VAC , 50A MAX.
FOR 220 VAC (AT 25 DEGREE C AMBIENT COLD START)
PFC: UP TO THE TARGET OF 95% @110V, FULL LOAD |
DC Output Specification
| Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
| +5V |
1 |
25.00 |
|
± 250mV |
± 1% |
50mV |
| +12V |
1 |
41 |
|
± 600mV |
± 1% |
120mV |
| -12V |
0 |
0.8 |
|
± 600mV |
± 1% |
120mV |
| +3.3V |
1 |
25 |
|
± 165mV |
± 1% |
50mV |
| +5VSB |
0.1 |
3.5 |
|
± 250mV |
± 1% |
50mV |

|